  • Oscilloscope Device

    NI

    Oscilloscope Devices are flexible, software‐defined instruments that are versatile enough for both time‐ and frequency‐domain measurements and are offered in industry-standard form factors like PCI and USB. They feature up to eight channels that can sample at speeds up to 2 GS/s. The devices also feature numerous triggering modes, deep onboard memory, and driver software API that includes data streaming and analysis functions.

  • Signal Analysis

    Synchronous Accumulation (Order Analysis) - ZETLAB Company

    Order analysis is one of the most convenient and efficient methods for diagnostics and balancing of rotating mechanisms and transmission gears. With an RPM  sensor and a vibration sensor, it is possible to study the time characteristics of gear vibration signals. It is a well-known fact that a signal from a vibration sensor is affected by signals from other sources. To tune out from the disturbing signals, the synchronous signal accumulation method is used. For each shaft rotation, the RPM sensor provides a rotation mark. This signal serves as a triggering strobe for the vibration sensor signal sweeping. The obtained signal sweeps are combined. All the sources of the signals related to the shaft frequency (frequency of rotation) are accumulated and increased in the accumulator linearly proportionally to the N number of rotations. All other signals that are not correlated with the shaft frequency are accumulated proportionally to N1/2 and in case of a greater number of averagings, the useful signal exceeds the interference level.

  • Materials Lab XM

    Ametek Scientific Instruments

    The Materials Lab XM product provides a fully integrated reference grade time domain and AC measurement platform. No need to switch sample connections between techniques. Time domain measurements include I-V (current voltage) characterization as well as fast pulse techniques. AC testing techniques include everything from single-sine analysis, to multisine / Fast Fourier Transform for faster low frequency analysis, to harmonics and intermodulation for testing linearity and breakdown of materials. Measurements of electrical impedance spectroscopy (EIS), admittance, permittivity and capacitance are all provided from the XM-studio MTS software platform, together with integrated equivalent circuit analysis functionality.

  • Current Probe

    PA-699 - PINTEK Electronics

    *High sensitivity: 1mA, High frequency: 1.5MHz. They are all 10 multiple calculation. Calculation is not making mistakes.*Max measuring current: +/- 40A DC / 80 Ap-p*Max sensitivity: ≧1mA*Bandwidth: DC ~ 1.5 MHz*Rising Time: 0.23 uS*Overload indicator*1V/A, 0.1V/A 2 ranges selectors*Input power switching (priority circuit) and battery available*Dispatching design, high durability

  • SafeOne RF Safety Monitor

    COMM-connect

    The SafeOne is a RF Safety Monitor covering the requirements set forth in WHO ICNIRP specifications. It has a very wide frequency range covering 30MHz to 10GHz, which makes it suitable for use in almost all antenna installations. Due to the innovative lightweight design, technicians can wear this at all times, without the need to constantly be observant of the state of the instrument. The SafeOne is powered with standard batteries, with 250 days of continuous operation.

  • Vector Network Analyzers

    ZND - Rohde & Schwarz GmbH & Co. KG

    The R&S®ZND network analyzer performs unidirectional measurements up to 4.5 GHz in the base model. It can be expanded to perform bidirectional measurements and the frequency range can be extended to 8.5 GHz. The large R&S®ZND touchscreen is easy to operate making it ideal for S-parameter measurements, even when many diagrams are needed. Time domain measurements can also be added for even more functions.

  • Digitizer Adapter Module For FlexRIO

    NI

    Digitizer Adapter Modules for FlexRIO can be used with a PXI FPGA Module for FlexRIO or the Controller for FlexRIO to create a high‐performance instrument with customizable firmware. With sampling rates from 40 MS/s to 3 GS/s and up to 32 channels, these modules cover a wide range of requirements for both time- and frequency‐domain applications. Digitizer adapter modules also provide digital I/O capability for interfacing with external hardware.

  • Accelerometers

    Monitran Ltd.

    Monitran General Purpose Analysis Sensors are ideal for use with portable and on-line vibration analysers, providing the user with a complete spectrum of vibration intensity against frequency. Changes in this spectrum allow the user to determine the health of the machinery to which the sensor is attached. Most analysers will store the spectral values and monitor changes over a period of time, allowing prediction of expected component life and enabling efficient planning of maintenance schedules.

  • KPG 24kV VLF Test Set

    Kilovolt Prueftechnik Chemnitz GmbH

    The portable cable test set KPG 24kV VLF is used for testing of medium voltage cables in accordance to the standards IEC 60502-2, CENELEC HD 620 & 621, DIN VDE 0276/620 & 621 and IEEE 400.Test is carried out with a low strain practice with VLF (very low frequency) test voltage of preferably 0.1Hz.VLF testing enables detection of damages of insulation within shortest test time.

  • PSG Signal Generators

    Keysight Technologies

    Generate trusted microwave signals: get metrology-grade frequency & level accuracy with excellent distortion & spurious characteristicsRely on the highest quality signals from pure CW tones with 1 W of power to complex, vector-modulated signals with 4 GHz bandwidthReduce the time you spend on signal creation with Signal Studio softwareTake advantage of increased performance, flexibility & speed when you replace a legacy source with the code-compatible PSG

  • Balance Thermocouple Power Sensor, DC To 50 GHz

    N8487S - Keysight Technologies

    The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.

  • Balance Thermocouple Power Sensor, DC To 18 GHz

    N8481S - Keysight Technologies

    The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.

  • Single Channel Instrument for General Acoustic / Vibration Measurements

    SVAN 979 - SVANTEK Sp. z o.o.

    SVAN 979 is the most advanced and powerful single channel instrument for general acoustic and vibration measurements ever made. The list of the instrument outstanding features and functionalities includes:- high accuracy sound and vibration measurements- most powerful frequency analysis package- time-domain (WAV) and Audio Events recording to Micro SD card- very high dynamic measurement range- extremely flat frequency response (digitally compensated)- extremely flexible set of interfaces (USB, Bluetooth, IrDA, RS232 and more)- USB Host port providing very flexible functional extensions capabilities- firmware ready for GPRS and WLAN communication (USB Host port)- GPS time synchronisation

  • Vector Signal Generator

    SGT100A - Rohde & Schwarz GmbH & Co. KG

    The R&S®SGT100A has a clear focus on automated environments with high speed and a compact design. The radio frequency chain has been optimized for the fastest frequency and level switchover times. In the baseband, the multisegment waveform mode helps users quickly switch from one test signal to the next. Though compact in size, the R&S®SGT100A has excellent RF characteristics (signal quality and level accuracy). Maximum output level, level repeatability and excellent EVM performance are key characteristics in production environments. Equipped with a LAN and USB interface, the R&S®SGT100A enables remote control of test equipment in automated applications.

  • Output Characteristic Analyzer of Electronic Ballast

    UI2002 - Lisun Electronics Inc.

    • Measure lamp voltage, lamp current, lamp power, oscillatory frequency, filament current, guided cathode current, and crest factors • Measure changing curves and values of startup lamp voltage, lamp current, filament current, cathode current from 0 to 5 seconds, as well as the pre-heat time • Accuracy: Class 2 • Data and curves printable. All the data and curves can be displayed after being connected with PC